THE SINGLE-PHASE HYBRID INVERTER WITH DEMAND-ORIENTED BACKUP POWER
INPUT DATA
Number of MPP trackers | 2 |
---|---|
Max. PV input power
|
3810 W |
Max. input current (Idc max)
|
22 / 12 A |
Max. short circuit current, module array
|
33 / 18 A |
DC input voltage range (Udc min – Udc max)
|
65 – 600 V |
Feed-in start voltage (Udc start)
|
80 V |
Nominal input voltage (Udc,r)
|
400 V |
MPP voltage range (Umpp min – Umpp max)
|
200 – 530 V |
Usable MPP voltage range | 65 – 530 V |
Number of DC connections | 2+2 |
Max. PV generator power (Pdc max)
|
5,52 kWpeak |
OUTPUT DATA
AC nominal output (Pac,r)
|
3680 W |
---|---|
Max. output power (Pac max)
|
3680 VA |
Max. grid power demand | 3680 VA |
Max. AC output current | 23,7 A |
Grid connection (Uac,r)
|
1~ NPE 220/230 V |
AC voltage range (Umin – Umax)
|
155 – 270 V |
Frequency (fr)
|
50 / 60 Hz |
Frequency range (fmin – fmax)
|
45 – 65 Hz |
Total harmonic distortion | < 2 % |
Power factor (cos φac,r)
|
0,8 – 1 ind,/cap, |
Back-up power | 1~NPE 220 V / 230 V |
GENERAL DATA
Width
|
474 mm |
---|---|
Height
|
530 mm |
Depth
|
165 mm |
Weight | 15,38 kg |
Weight incl. packaging | 19 kg |
Degree of protection | IP66 |
Protection class | 1 |
Overvoltage category (DC / AC) 1)
|
2 / 3 |
Night-time consumption | < 10 w 10=”” w=””> |
Inverter design | Transformerless |
Cooling | Regulated air cooling |
Installation | Indoor and outdoor installation |
Ambient temperature range | -40°C – +60°C |
Permitted humidity | 0 – 100 % |
Max. altitude 2)
|
4000m |
DC PV connection technology | 4x DC+ and 4x DC- push-in spring terminals 2.5 – 10 mm² |
DC battery connection technology | 1x BATT+ and 1x BATT- push-in spring terminals 2.5 – 10 mm² |
AC connection technology | 3 pole AC push-in spring terminals 2.5 – 10 mm² 3 pole backup power push-in spring terminals 1.5mm² – 10mm² 2x PE-screw terminals 2.5 – 16 mm² and 3x 2,5 – 10mm² |
Certificates and compliance with standards | IEC 62109, IEC 62909, AS/NZS 4777.2, CEI 0-21, ABNT BNR 16149 and 16150, IEC 62116, IEC 61727 |
Back-up power functions | PV Point, Full Backup&nbsp;<sup>4)</sup> |
Compatible batteries | BYD Battery-Box Premium HVS/HVM&nbsp;<sup>5)</sup> |
Interference emission class | B |
EFFICIENCY
Max. efficiency (PV – grid) | 97,6 % |
---|---|
European efficiency (ηEU) | 95,6 / 97,0 / 96,3 (200Vdc / 400Vdc / 530Vdc) |
η at 5% Pac,r 3)
|
85,3 / 90,2 / 87,9 (200Vdc / 400Vdc / 530Vdc) |
η at 10% Pac,r 3)
|
89,5 / 93,2 / 91,5 (200Vdc / 400Vdc / 530Vdc) |
η at 20% Pac,r 3)
|
94,0 / 96,1 / 95,3 (200Vdc / 400Vdc / 530Vdc) |
η at 25% Pac,r 3)
|
94,8 / 96,6 / 96,0 (200Vdc / 400Vdc / 530Vdc) |
η at 30% Pac,r 3)
|
95,4 / 96,9 / 96,3 (200Vdc / 400Vdc / 530Vdc) |
η at 50% Pac,r 3)
|
96,3 / 97,4 / 97,0 (200Vdc / 400Vdc / 530Vdc) |
η at 75% Pac,r 3)
|
96,6 / 97,5 / 97,3 (200Vdc / 400Vdc / 530Vdc) |
η at 100% Pac,r 3)
|
96,7 / 97,5 / 97,3 (200Vdc / 400Vdc / 530Vdc) |
MPP adaptation efficiency | 99,9 |
PROTECTION DEVICES
DC insulation measurement | Yes |
---|---|
Overload behaviour | Operating point shift. Power limitation |
DC disconnector | Yes |
DC Reverse polarity protection | Yes |
INTERFACES
WLAN / 2x Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) |
---|---|
6x digital in/out + 6x digital in | Interface to ripple control receiver, energy management |
USB 2.0 (A-socket) | 1 A supply |
Emergency stop (WSD) | Yes |
Datalogger and web server | Included |
2x RS485 | Modbus RTU SunSpec (third-party supplier) / Fronius Smart Meter, battery, Fronius Ohmpilot |
OUTPUT DATA PV POINT
Max continuous output power | 3000 VA |
---|---|
Nom. output current (Iac max)
|
13 A |
Grid connection | 1 ~ NPE 220 V / 230 V |
Frequency | 50 Hz / 60 Hz |
Switchover time | 90 s |
BATTERY CONNECTION
Number of DC connections | 1 |
---|---|
Max. input current (Idc max)
|
22 A |
DC input voltage range (Udc min – Udc max)
|
150 V – 455 V |
Max. input / output power (Depending on the connected battery) | 3810 W |
Max. AC charging power | 3680 W |