Wind Turbine “ANTARIS 12 kW” Grid feed-in/off-grid SW10
HS-Code: 85023100
Technical details:
Alternator
– Permanent generator brushless without gearing,
maintenance-free
– High Coefficient with powerful magnets
(NdFeBo-Magnet, 150° C temperature-resistant) – 3-Phase-Current
– Separate Rectifier
– Direction of Rotation arrange in any way
– Voltage 0-1000 Volt
– Loading begins at ca. 60 rpm
– Electric power max. 18 kW
– Rampant output curve by increase number
of revolutions
– Weight: ca. 160 kg
– Casing aluminium, foot-mounting
– House-case in GFK
– Protection class IP56
– with temperaturecontrol for alternator
Rotor with Housing-case
– Hub connection with Aluminium-Flange and
press-washer
– Stainless-steel bolted connection
– 3 Blades about Fiber-glass / Carbon-Fiber
laminated aorodynamic profile
– Diameter 6,50 m effective circular area
– Blade-Weight for 1 pcs: 18,0 kg
– Dynamically balanced
– Direction of Rotation ahead right
– Number of Revolutions maximum 240 rpm – GFK-Spinner cap
– Blade colour “white”
– Weather vane
Absolutely weather Proof HDPE “white”
Square pipe high temperature galvanized steel for the
carry components
All bolted connection about stainless steel and with locking fastener for nuts
– Steel console for carrying the Generator intended as connection assembly
– with slip rings (5 x 70A) for discharging power – Steel tube with flange DN 200, PN 16
– All steel parts are hot galvanized
Storm covering:
– Rotor-blade positioning (“helicopter position”)
– Voltage monitoring with 20.0 kW braking resistance – Generator short-circuit
– Temperature monitoring from Alternator and Inverter
2 pcs. 6.5 kW braking resistance (Dumpload) 25 Ohm
1 pcs. Grid Inverter: Smart!wind 10 – Inverter for wind turbines to grid feed
– Dimensions 656x472x234mm – Weight 42 KG
– Degree of protection IP54
– Cooling
Passively controlled air / fan demand
– Operating temperature range -25 ° C. .. +40 ° C – Maximum overall efficiency. 94%
– Consumption <18 W – Standby
<83 W – active feed
– IGBT inverter grid side B6 – Number of phases 3
– Output (rated) 10 kW
– Output voltage
400 VLL – Rated
318 … 460 VLL – permissible range – Output current (nominal) 0 … 16 A
– Output frequency 0 Hz … 150 Hz
– Separation concept
transformer less – no galvanic isolation – Current THD <3%
– Power factor – cos phi
regulated at 1 – to control VDE-AR-N 4105 – Short-circuit protection: current control
– grid / system protection – ENS
Integrated according to VDE-AR-N 4105
Explorer inkl. PEAKCAN Dongle
Windsensor mit Heizung Kleinwindgeber schwarz mit Heizung Ausgang 0-100 Hz
round pole12 m HS-Code: 73082000
composed of 1 piece with flange prepared for ANTARIS 12 kW turbine
former plate for circular beam pole + lifting element for 12 m pole
circular beam 12 m circular beam 12 m pole
circular beam lifting element
circular beam lifting element for 7 m pole
tilting device for pole
tilting device for pole H=7 m, 9.20 m und 12 m to produce and delivery,
hot dip galvanised, included wire
Engineering for pole
statics, calculation grounding, drawing and parts lists
Technical Specifications ANTARIS 12.0 kW
Working grid feed in at 2.5 m/sec. wind speed after start up, depending on the repeller. Purpose built for inland areas with low untill moderate wind speed. From an average wind speed with 6.0 m/sec. we use a repeller with 5.8 m diameter!
Generator
- Permanent-magnet rotor, brushless, gearless, maintenance-free
- Extremely strong permanent magnets for a high level of efficiency (NdFeBo permanent magnets, resistent to temperatures up to 150° C)
- Special ball bearings for reliably taking up radial and axial forces
- 3-phase current
- Separate rectifier
- Either direction of rotation
- Voltage 0-1000 VDC
- Start of feed-in at approx. 65 rpm
- Power: 12.000 watts at 255 rpm and 500 VDC
- Evenly rising power curve
- Weight: 160 kg
- Aluminium housing, surface cooling, base anchoring
- Protection class IP56
Rotor
- Hub connection with aluminium flange and pressure-relief plate
- Stainless-steel screw connections with locknuts
- Three rotor blades in glass-fibre / carbon-fibre laminate
- Computer-designed aerodynamic profile
- Winglets on blade tips to minimise noise
- Approx. 6.50 m diamater (optionally 5.8 m > 6.0 m/s average wind speed)
- Weight of each blade: approx. 14.0 kg
- Dynamically and statically balanced
- Direction of rotation anticlockwise viewed from front
- Max. rotational speed 255 rpm
- GRP spinner cap
- Rotor colour to client specification
Support element comprising
- Wind vane (weatherproof HDPE, off-white, slightly transparent)
- Square stainless-steel tube as support element
- All screw connections in stainless steel and fitted with locknuts
- Steel bracket as support for generator, configured for plug-in connection with azimuth bearing, fully galvanised
- Protected by patented rotor-blade positioning system
- Mast adapter with flange connector (tube 220 mm)
Storm protection
- Rotor-blade positioning (“helicopter position”)
- Voltage monitoring with 18.0 kW braking resistance
- Generator short-circuit
- Temperature monitoring from Alternator and Inverter
Control cabinet
- Control system with Turbine Power Curve
- 3-phased grid-feed in with Smart!wind Inverter 10.0 kW
- Control electronics with 3-phased turbine controller
- Connections / plug connectors protected against polarity reversal
- Controlling of the 3 alternator phases during turbinemode
- Reset switch with key (removable)
- Emergency-OFF switch
- 18.0 kW braking resistance
- Rectifier, display etc.